Contact Us CH | EN

Rubber Cables

Home > Cable & Wire

FVN
Nylon Cables
  • Descriptions
  • Specifications
  • Installation

Standards

1. Reference Standard: JB/T 10261-2001
2. Rated Voltage: 300/500V,450/750V
3. Operating Temperature: -60℃-105℃

Applications

Applicable to aircraft low-voltage lines, highway test equipment installation and inductive coil dedicated line (electronic police line, to sense coil line).

Parameters

1. Multi-stranded tinned copper wire, strong corrosion resistance
2. Special heat-resistant PVC insulation, heat-resistance, anti-aging
3. Jacket with high quality nylon material, wear-resistant, waterproof, cold-resistance, anti-corrosion and other characteristics
4. In the relative humidity of 98%, cable can be used normally
5. laying bending radius should not be less than 6 times the finished diameter
6. Shielded wire can be produced, enhanced cable use characteristics.
Section Area Conductor Insulation Thickness Sheath Thickness O.D. Max. Conductor Resistance at 20
Unscreened Screened
mm2 No./mm mm mm mm mm Ω/km
0.3 16/0.15 0.35 0.12 1.7 2.2 71.2
0.5 28/0.15 0.35 0.12 2 2.5 40.1
0.75 42/0.15 0.35 0.12 2.1 2.6 26.7
1 32/0.20 0.35 0.14 2.3 2.7 20
1.5 48/0.20 0.4 0.14 2.7 3.2 13.7
2.5 49/0.25 0.5 0.14 3.6 4.1 8.21
4 49/0.32 0.6 0.16 4.4 4.9 5.09
6 84/0.30 0.6 0.16 5.1 5.6 3.39
10 19*7/0.32 0.9 0.2 6.6 7.1 1.95
16 19*7/0.39 1 0.2 8.3 8.9 1.24

 

Shanghai Aipu Waton Electronic Technology(Group)Co.,Ltd