Standards

1. Reference Standard: IEC 61196, BS EN 50117, UL13, UL444
2. Rated Temperature: 70℃
3. Rated Voltage: 300V

Applications

Drop cable for interior application

Characteristics

1. Max. Operating Temp of Conductor. 70℃
2. Conductor with high quality copper, low signal transmission attenuation
3. RG59 & RS-485 insulation material for high-quality PE,anti-aging, low-temperature resistance, anti-chemical corrosion, non-toxic and other characteristics can be customized.
4. Power cable insulation material for high-quality PVC, anti-aging, low-temperature resistance, anti-chemical corrosion, non-toxic and other characteristics can be customized.
5. Sheath material for high-quality PVC, anti-aging, wear resistance, waterproof, anti-chemical corrosion, non-toxic and other characteristics can be customized.
6. RS-485 is shielded with aluminum foil, effectively blocking the external electromagnetic interference.
7. Impedance (ohms):50.0

 

Structure

Conductor

Insulation

Shield

 Sheath

Outer Sheath (mm)

Max. Conductor DCR at 20(ohm/km)

Insulation Resistance @70 (MΩ/KM)

MTRL

Dia. 

AWG

MTRL

Dia.

Al-foil

Braid

MTRL

Nom Thickness (mm)

O.D.

(mm)

(mm)

MTRL

Coverage

(mm)

RG59

BC

0.58

23

Solid PE

3.6

 

BC

80%

PVC

0.95

5.80

13.80

70.0

0.013-0.014

Power

BC

16/0.2

20

PVC

1.90

 

 

 

PVC

0.60

5.00

39.0

RS-485

TC

7/0.20

24

Solid PE

1.7

Al-foil

 

 

PVC

0.60

4.80

92.3

 

 

 